TECHNICAL SPECIFICATION TABLE

Inlet air temperature 35' C
Pressure 7barg

Maximum working condition will be:

Maximum inlet air temperature: 50' C
Maximum ambient temperature: 50' C
Maximum inlet air pressure: 13barg
Design pressure: 16barg

Average required air for regeneration 12% (in stable operation)

Standard feeding source: 1Ph/230V-240V/50hz-60Hz

NOTICE: Please specify dew Point Pressure at order time

AIR QUALITY BASED ON ISO 8573.1

The outlet Compressed Air from HDT Dryers has the highest level of international standard.

TECHNICAL SPESIFICATIONS OF DRYER TOWER

  • Carbon steel made Towers with powder paint, designed based on the latest European standard.
  • Design of each tower's volume is based on optimum air movement through the surface and the minimum pressure drop (Maximum 0.21)
  • Compact package & non influence to avoid desiccant movement & pollution.
  • Compressed air movement through desiccant is from down to up.(Air inlet is in bottom of each column & the outlet is on the top).To keep heavy particles & water drops in the bottom of column & their exit to the outside at regeneration time.

DESICCANT MATERIAL SPESIFICATIONS

The HDT series dryers uses molecular sieve to absorb the humidity.
These materials have maximum quality with below special specifications:

  • They are resistant to high temperature & are not damaged or affected in humid, condition.
  • They are suitable for dew points up to -70' C
  • Its surface resistance is higher than other materials & have minimum surface scrape compared to the other kind of absorbents (This will cause the long life of the dust filter element).
  • Maximum operating time is between 3-5 years if they are correctly used.